Outside fresh-air connection, Exhaust and fresh air intake locations, Installation – Enviro EF4 User Manual

Page 16

background image

16

Outside fresh air is mandatory when installing this

unit in airtight homes and mobile homes.

When connecting to an outside fresh air source, do not use

plastic or combustible pipe. Only 15⁄8” minimum (42 mm)

ID (inside diameter) steel, aluminum or copper pipe should

be used. It is recommended, when you are installing a fresh

air system, to keep the number of bends in the pipe to a

minimum.

Installation

O

UTSIDE

F

RESH

-A

IR

C

ONNECTION

:

� ��

��� ���

��������

�����

�������

����

Figure 14: Outside Air Connection.

E

XHAUST

A

ND

F

RESH

A

IR

I

NTAKE

L

OCATIONS

:

EXHAUST

Freestanding

Insert

Base to center of flue

15 1⁄4” (38.8 cm)

7 7⁄8”

(20.0 cm)

Side to center of flue

5 7⁄8”

(14.8 cm)

5 3⁄4”

(14.6 cm)

Center of unit to center of flue

5

3

/

16

(13.2 cm)

5

3

/

16

(13.2 cm)

FRESH AIR INTAKE.

Base to center of intake

10 1⁄8” (25.9 cm)

2

15

/

16

” (7.4 cm)

Side to center of intake

8”

(20.2 cm)

8

1

/

16

(20.5 cm)

Center of unit to center of flue

3

1

/

16

(7.8 cm)

3

1

/

16

(7.8 cm)

INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENTING MANUFACTURER

��

��������

��

��������

��������

��

��������

��

�������

��

��������

������

��

��

�������

��������

��

��������

��

�������

��

��������

Figure 15: EF4 Freestanding Inlet and Outlet Location.

Figure 16: EF4 Fireplace Insert Inlet and Outlet Location.