Clearances to combustibles - freestanding, Clearances to combustibles - fireplace insert, Installation – Enviro EF4 User Manual

Page 13

background image

Installation

C

LEARANCES

TO

C

OMBUSTIBLES

- F

REESTANDING

:

When installing this unit on a combustible floor (eg. wood linoleum) a non-combustible hearth pad must

be under the unit. The pad must extend at least the width of the appliance [22” (558 mm)] and at least

the depth of the appliance plus 6” (150 mm) in front of the appliance [27 1⁄2” (699 mm)].

Side wall to unit

- 6 inches (15 cm)

Back wall to unit

- 2 inches (5 cm)

Corner to unit

- 2 inches (5 cm)

Door front to edge of floor protection

- 6 inches (15 cm)

48"

(122 cm)

48"

(122 cm)

36"

(91cm)

��

���� ���

��

��� ���

��

��� ���

��

���� ���

���� ����

��

��

��

����

���

���

����� ����������

Figure 8: EF4 Freestanding Clearance to Combustibles.

Minimum Alcove width - 36 inches (91 cm)

Minimum Alcove height - 48 inches (122 cm)

Maximum Alcove depth - 48 inches (122 cm)

Figure 9: EF4 Freestanding Minimum Alcove Size.

C

LEARANCES

TO

C

OMBUSTIBLES

- F

IREPLACE

I

NSERT

:

Side wall to unit

- 9 inches (22.9 cm)

Mantel projection

- 10 inches (25.4 cm)

Mantel to top of unit

- 8 inches (20.3 cm)

Facing on masonry fireplace edge

- 9 inches (22.9 cm)

Minimum solid fuel burning fireplace opening:

Height

- 211⁄8”

(53.7 cm)

Width

- 22”

(58.9 cm)

Depth

- 211⁄2”

(54.6 cm)

10" (25.4 cm) Mantel

9"

(22.9 cm)

8"

(20.3 cm)

S

id

e

W

al

l

Figure 10: EF4 Fireplace Insert Clearance to Combustibles.

13

These dimensions are minimum clearances but it is

recommended that you ensure sufficient room for

servicing, routine cleaning and maintenance.