Clearances to combustibles - freestanding, Clearances to combustibles - fireplace insert, Installation – Enviro EF4 User Manual
Page 13
Installation
C
LEARANCES
TO
C
OMBUSTIBLES
- F
REESTANDING
:
When installing this unit on a combustible floor (eg. wood linoleum) a non-combustible hearth pad must
be under the unit. The pad must extend at least the width of the appliance [22” (558 mm)] and at least
the depth of the appliance plus 6” (150 mm) in front of the appliance [27 1⁄2” (699 mm)].
Side wall to unit
- 6 inches (15 cm)
Back wall to unit
- 2 inches (5 cm)
Corner to unit
- 2 inches (5 cm)
Door front to edge of floor protection
- 6 inches (15 cm)
48"
(122 cm)
48"
(122 cm)
36"
(91cm)
��
���� ���
��
��� ���
��
��� ���
��
���� ���
���� ����
��
�
�
�
��
�
��
����
���
���
����� ����������
Figure 8: EF4 Freestanding Clearance to Combustibles.
Minimum Alcove width - 36 inches (91 cm)
Minimum Alcove height - 48 inches (122 cm)
Maximum Alcove depth - 48 inches (122 cm)
Figure 9: EF4 Freestanding Minimum Alcove Size.
C
LEARANCES
TO
C
OMBUSTIBLES
- F
IREPLACE
I
NSERT
:
Side wall to unit
- 9 inches (22.9 cm)
Mantel projection
- 10 inches (25.4 cm)
Mantel to top of unit
- 8 inches (20.3 cm)
Facing on masonry fireplace edge
- 9 inches (22.9 cm)
Minimum solid fuel burning fireplace opening:
Height
- 211⁄8”
(53.7 cm)
Width
- 22”
(58.9 cm)
Depth
- 211⁄2”
(54.6 cm)
10" (25.4 cm) Mantel
9"
(22.9 cm)
8"
(20.3 cm)
S
id
e
W
al
l
Figure 10: EF4 Fireplace Insert Clearance to Combustibles.
13
These dimensions are minimum clearances but it is
recommended that you ensure sufficient room for
servicing, routine cleaning and maintenance.