beautypg.com

SMA 485 Data Module User Manual

Page 16

background image

GND

5

5

Data+

2

2

Data-

7

7

5  Connection

SMA Solar Technology AG

16

485i-Module-IA-en-18

Installation Manual

3. Press the seal out of the cable gland from the inside.

4. Route the cable from the outside into the inverter

through the loose swivel nut and the cable gland.

5. Remove one of the filler-plugs from the seal for each

cable.

6. Insert the cable into the seal.

7. Push the seal into the cable gland. Make sure that

any unused cable openings are sealed with filler-plugs.

8. Screw the swivel nut of the cable gland on lightly.
9. Remove or connect the terminator:

• If two cables are connected, open the spring clamp terminals of the plug with the connected

terminator and remove the terminator.

• If one cable is connected, the terminator in the unused plug must be connected in terminals

2 and 7.

10. Open the spring clamp terminals on the plug.
11. Connect the wires to the plug terminals and note down the colour of the wires. The cables can

be allocated to any plugs of your choosing.

Signal

485 Data Modules

RS485 bus Insulated wire colour