6.3 Error messages

If an error occurs, the Sunny Boy and Sunny Mini Central generate a message which depends on the
operating mode and the error detected.

Message

Description and corrective measure

!PV-Overvoltage!
!DISCONNECT DC!

Overvoltage at DC input.

Corrective measures

• Please contact your installer who will immediately disconnect the

PV generator from the inverter! Otherwise, the inverter may be
damaged.

• Your installer should check the DC voltage, as described in the

inverter installation guide.

ACVtgRPro

The 10-minute-average grid voltage is no longer within the permissible
range. This can be caused by either of the following:

• The grid voltage at the connection point is too high.
• The grid impedance at the connection point is too high.

The inverter disconnects to assure compliance with the voltage quality of
the grid.
Corrective measures

• Please contact your installer or the SMA Solar Technology

Serviceline.

Bfr-Srr

Internal measurement comparison fault or hardware defect.
Corrective measures

• Please contact your installer or the SMA Solar Technology

Serviceline if this problem recurs.

CAN

Internal communication fault.
Corrective measures

• Please contact your installer or the SMA Solar Technology

Serviceline if this problem recurs.

Check L-N-PE

L and N are swapped on the AC connection or PE is not connected (only
applies for Sunny Mini Central models 9000TL / 1000TL / 11000TL).
Corrective measures

• Please contact your installer to check the AC connection.

Check Varistor

At least one of the varistors is defective (only applies to Sunny Mini
Central models 9000TL / 1000TL / 11000TL).
Corrective measures

• Have your installer check the function of the varistors, as described

in the inverter installation guide.