6 Measurement Channels and Messages
If your inverter is equipped with a communication component, then numerous measurement channels
and messages to aid diagnosis can be transmitted.
The following abbreviations apply:
BFR: Operation control unit
SRR: Current control unit
6.1 Measuring Channels
Measuring
channel
Description
Balancer
Displays the currently active operating mode of the Sunny Mini Central, which
has been set via the operating parameter "PowerBalancer".
Earthfault / Riso Insulation resistance of the PV system before grid connection
E-total
Total amount of energy fed into the grid
Error
Identification of the current disturbance / error.
Error-Cnt
Number of errors which have occurred since the last reset
Event-Cnt
Number of events which have occurred
Fac
Grid frequency
Fault current
Differential current of the PV system (inverter and PV generator)
h-On
Total number of operating hours
h-total
Total number of grid-feeding operational hours
Iac
Grid current (active current)
Ipv
DC current
Is
Apparent current (applies only to inverters with Reactive Power Control)
Mode
Display of the current operating mode
Power On
Total number of grid connections
Pac
Generated AC power
Phase
The phase to which the inverter is connected. The phase (L1 - L3) is set via the
operating parameter "Grid connection".
PF
Displacement factor cos ϕ (applies only to inverters with Reactive Power
Control)
Qac
Reactive power (applies only to inverters with Reactive Power Control)
Sac
Apparent power (applies only to inverters with Reactive Power Control)
Serial Number
Serial number of inverter
Vac
Grid voltage
Vfan,
V-Fan
Fan supply voltage (only in inverters equipped with an active cooling system)