SMA FLX Pro 15 User Manual
Page 4
SMA Solar UK Ltd, Unit 2B Gemini Building, Sunrise Parkway, Linford Wood, Milton Keynes, MK14 6NP, UK
Tel: 01908 304850
Page 4 of 12
2. Introduction
This document explains how to update the software for
FLX Pro 15 and FLX Pro 17
Software version 3.10 to achieve G59/3 compatibility
Note:
The software update process can take up to 20 minutes. At the end of the update the inverter will
restart. Do not press any buttons on the inverter display or the PC while the update is in progress.
If an FLX inverter is delivered with G59/2 settings, you can change the settings without password
within the first hours after the installation. If you want to change the parameters of installed devices,
you may be asked for a password. You can receive the password from the SMA UK Service
department. Please see the Appendix B for contact details.
3. Update Guide for FLX Pro
3.1 Verify the Inverter Type
Verify that the network of inverters comprises FLX Pro types only.
o
Check front cover and product label to find the inverter type.
o
Proceed only when the inverters are of type FLX Pro.
Ensure Ethernet connection is established between the inverters.
o
Check cabling
Note: For illustrations please see the ‘Appendix A’.