beautypg.com

SMA SB 1.5-1VL-40 User Manual

Page 54

background image

Climatic category in accordance with
IEC 60721-3-4

4K4H

Environmental category

Outdoors

Pollution degree outside the inverter

3

Pollution degree inside the inverter

2

Operating temperature range

−40°C to +60°C

Maximum permissible value for relative humid-
ity, non-condensing

100 %

Maximum operating altitude above mean sea
level

3,000 m

Noise emission, typical

< 25 dB

Power loss in night mode

2 W

Maximum data volume per inverter with Speed-
wire/Webconnect

550 MB/month

Additional data volume when using the Sun-
ny Portal live interface

600 kB/hour

WLAN range in free-field conditions

100 m

Quantity maximum detectable WLAN networks

32

Topology

Transformerless

Cooling method

Convection

Degree of protection in accordance with
IEC 60529

IP65

Protection class in accordance with IEC 62103

I

Grid configurations

TN-C, TN-S, TN-CS, TT (if V

N_PE

 < 30 V), IT, Delta

IT, split phase

National standards and approvals, as per
04/2015*

AS 4777, C10/11/2012, CEI 0-21,

EN 50438:2013, G83/2, NEN-EN50438,

VDE-AR-N 4105, VFR2014, DIN EN 62109-1,

IEC 62109-2

* IEC 62109-2: In order to meet the requirements of this standard, there must be a link to Sunny Portal

with the fault alert via e-mail activated.

Climatic Conditions

Installation in accordance with IEC 60721-3-4, Class 4K4H

Extended temperature range

−40°C to +60°C

11 Technical Data

SMA Solar Technology AG

Operating Manual

SB15-25-BE-en-10

54

This manual is related to the following products: