Remote contr ol, cont’d – Extron Electronics MPX Plus 866 A Rev. A User Manual
Page 18

Refer also to the
MPX Plus 866 A User’
s Manual
at www
.extron.com.
Refer also to the
MPX Plus 866 A User’
s Manual
at www
.extron.com.
Command
ASCII command
(host to switcher)
Response
(switcher to host)
Additional description
Audio output volume
Set the audio volume to a specific
value
X@
*
X(
V
Out
X@
•Vol
X(]
Example:
1*50v
Out01•Vol50
]
Set output 1 volume to 79%.
Increment volume
X@
+V
Out
X@
•Vol
X(]
Increase volume by 1 step.
Example:
1+V
Out01•Vol51
]
Decrement volume
X@
-V
Out
X@
•Vol
X(]
Decrease volume by 1 step.
Read output volume
X@
V
X(]
Save and recall presets
N
Presets saved from the front panel are always global ties presets, which are complete, ties only, configurations that overwrite all ties in the
current configuration when recalled).
Presets recalled using any operator interface can be either global ties presets or partial presets.. Partial presets are created in the DSP
Configurator program, and can include audio parameters set in the DSP and only selected ties. When recalled, partial presets overwrite only
those portions of the current configuration that are part of the preset.
N
If you try to recall a preset that has not been not saved, the matrix switcher responds with the error code
E11.
Save the current configuration as a
global ties preset
X1),
Spr
X1)]
Command character is a comma.
Example:
9
,
Spr09
]
Save current ties as preset 9.
Recall a global ties or partial preset
X1).
Rpr
X1)]
Command character is a period.
Example:
5
.
Rpr05
]
Recall preset 5, which overwrites all
(global ties preset) or some (partial preset)
of the current configuration.
Command
ASCII command
(host to switcher)
Response
(switcher to host)
Additional description
Front panel lock (executive mode)
Lock all front panel functions
1X
Exe1
]
Enable Lock mode 1.
Lock advanced front panel functions
2X
Exe2
]
Enable Lock mode 2.
Unlock all front panel functions
0X
Exe0
]
Enable Lock mode 0.
View lock status
X
X1!]
Information requests
Information request
I
V14X12•A14X12
]
V14X12 is the video matrix size.
A14X12 is the audio matrix size.
Request part number
N
60-796-01
]
Query controller firmware version
Q
X1@]
Example:
Q
1.23
]
The factory-installed controller firmware
version is 1.23 (sample value only).
N
X@
= Output number
01 – 06
X(
= Volume adjustment range
00 – 64 (1 dB/step except for 0-to-1, which is 22 dB) (default = 64 [0 dB])
X1)
= Global ties preset or partial preset #
00 - 32
N
X1!
= Lock mode
0, 1, or 2
X1@
= Firmware version number to second decimal place (x.xx)