Programming: Q Parameters

9.6

Checking and changing Q parameters

9

258

TNC 640 | User's Manual for DIN/ISO Programming | 5/2013

9.6

Checking and changing Q parameters

Procedure

You can check Q parameters in all operating modes (when writing,

testing and running programs) and also edit them.

If you are in a program run, interrupt it if required (for example,

by pressing the machine STOP button and the INTERNAL STOP

soft key). If you are in a test run, interrupt it.

Call Q-parameter functions: Press the Q INFO soft

key or the Q key.

The TNC lists all parameters and their current

values. Use the arrow keys or the GOTO key to

select the desired parameter.

If you would like to change the value, press the

EDIT CURRENT FIELD soft key, enter the new

value, and confirm with the ENT key.

To leave the value unchanged, press the PRESENT

VALUE soft key or end the dialog with the END

key.

The parameters used by the TNC internally or in

cycles are provided with comments.
If you want to check or edit local, global or string

parameters, press the SHOW PARAMETERS Q QL

QR QS soft key. The TNC then displays the specific

parameter type. The functions previously described

also apply.