beautypg.com

Operating parameter list – HEIDENHAIN ND 510 v.2 User Manual

Page 7

background image

Model

Signal

period [µm]

Reference

marks

P43

Display step
(unit: P01)
mm inches

Subdi-
vision
P32

Operating Parameter List

– cont'd.

Parameter

Meaning

Function / Effect

Setting

Counting

Normal

(Direction: Positive)

direction

A

Inverse

(Direction: Negative)

Signal period of encoder

A

(

Period:) 2, 4, 10, 20, 40, 100, 200

Subdivision of the encoder signals

A

(

Subdivision:) 4, 2, 1, 0.8, 0.5, 0.4, 0.2, 0.1

Select

Error compensation not active

error

Linear error compensation active

compensation

Non-linear error compensation active

Linear error compensation

1)

A

Compensation – 99 999 < P41 < + 99 999 [µm/m]

Reference

One reference mark

marks

A

Distance-coded with 500

SP

(SP = signal period)

Distance-coded with 1000

GP

(e.g. for LS 303 C / LS 603 C)

Distance-coded with 2000

SP

Distance-coded with 5000

SP

Encoder

Monitoring off

(Alarm Off)

Encoder

monitoring

A

Monitoring on

(Alarm On)

Axis display

A

Display measured position

(

Axis)

Do not display measured position /
no encoder

Function of

Resets display to zero

CL key

Does not reset display to zero

1)

Calculate the entry value for P41
Example:
Displayed measuring length La = 620.000 mm

Actual length (determined with, for example, the VM 101 comparator
system from HEIDENHAIN) Lt = 619.876 mm

Length difference

L = Lt – La = –124 µm

Compens. factor k: k =

L / La = –124 µm / 0.62 m = –200 [µm/m]

Parameter Settings for HEIDENHAIN Linear Encoders

LS 303

20

one

single 0.005 0.000 2

4

LS 603

dist.c.

1 000

0.01

0.000 5

2

LB 302

40

one

single

0.01

0.000 5

4

LIDA 10x

dist.c.

2 000

LB 3xx

100

one

single

0.025

0.001

4

dist.c.

1 000

0.05

0.002

2

0.1

0.005

1

Example:

Linear encoder with signal period s = 20 µm
Desired display step a = 0.005 mm
Subdivision P32 =

=

=

=

= 0.001

•••••

s / a = 4

This manual is related to the following products: