beautypg.com

Nd 280 setup, Functions – HEIDENHAIN ND 280 Quick Start User Manual

Page 6

background image

DR. JOHANNES HEIDENHAIN GmbH

Dr.-Johannes-Heidenhain-Straße 5

83301 Traunreut, Germany

{ +49 (8669) 31-0

| +49 (8669) 5061

E-mail: [email protected]
www.heidenhain.de

2

Installation Setup

1.

Press the soft key shown in the
fi gure above.

2.

Press the soft key shown in the fi gure
above and enter the passcode 95148.

Operating Parameters

Important parameters are in bold type.

1.

Encoder Setup

Encoder Type

(linear, rotary).

Encoder Signal: Automatically

determined.
Signal Period:

Depends on the

encoder.
Reference Mark:

Depends on the

encoder.
Count Direction:

Select the proper

count direction.
Error Monitor (as required).

2.

Display Confi guration

Set the display resolution.

3.

Counter Settings

Lock or release the keypad.

Second decimal point (after 3 decimal

places).
Reset all parameters to factory default

settings.

4.

Error Compensation

Error Compensation:

Select OFF,

Linear or Non-linear, and enter the
data.

5.

Interface Settings

As required.

6.

Diagnostics

As required.

Job Setup

Press the SETUP soft key to open the
menu.

1.

Units

Select mm or inches, or degrees/minutes/
seconds (DMS), decimal degrees (DEG)
or rad (display in status bar).

2.

Scale Factor

Deactivate the scale factor, or select the
desired scale factor (display in status bar).

3.

Value for Datum Point

Enter numerical value for datum setting
over switching input or with PRESET
soft key.

4.

Stopwatch

Start the stopwatch (elapsed time is
displayed in status bar).

5.

Console Adjustment

Select the brightness and activate the
display saver.

6.

Language

Select the proper conversational
language.

Before starting a measurement

Ensure that the distance or angle

actually traversed matches the displayed
value and direction. Deviations may be
due to the following causes:

Signal period

Counting direction

Error compensation

Scale factor

Distance-to-go display

REF Reference Mark Evaluation

The ND 280's REF reference mark
evaluation feature automatically
re-establishes the relationship between
axis-slide or measuring-probe positions
and display values that you last defi ned
by setting the datum.

If you do not use the REF feature,

the datums will be lost once the ND is
switched off.

Actual Value/Distance-To-Go

In the Actual Value operating mode, the
ND always displays the current actual
position of the encoder, relative to the
active datum.
In the Distance-To-Go operating mode,
you enter the desired nominal position
and simply traverse to the display value
zero.

The distance-to-go is displayed with

a reversed algebraic sign. For example,
the distance-to-go has a positive sign if
the axis direction from the actual towards
the nominal position is negative.

I: Actual

position

S: Nominal position
R: Distance-to-go

ND 280
Setup

For detailed description, see www.heidenhain.de

Functions