beautypg.com

Features and controls, Instrument cluster, Diagnostic display code definitions – Polaris 2015 ATV Sportsman ACE 570 User Manual

Page 46: Diagnostic codes

background image

44

FEATURES AND CONTROLS

Instrument Cluster

Diagnostic Display Code Definitions

Open Load: There is a break in the wires that lead to the item listed in
the chart (injector, fuel pump, etc.), or the item has failed.

Short-to-Ground: The wire is shorted to ground between the electronic
control unit and the item listed in the chart.

Shorted Load: The wires leading to the item listed in the chart are
shorted together, or the item has shorted internally.

Short-to-Battery: The wire leading from the item listed in the chart to
the electronic control unit is shorted to a wire at battery voltage.

Diagnostic Codes

Component

Condition

SPN

FMI

Accelerator
Position 2

Data Erratic, Intermittent Or Incorrect

29

2

Voltage Above Normal, Or Shorted To High Source

29

3

Voltage Below Normal, Or Shorted To Low Source

29

4

Throttle Position
Sensor 1

Data Valid But Above Normal Operational Range - Most
Severe Level

51

0

Data Valid But Below Normal Operational Range - Most
Severe Level

51

1

Data Erratic, Intermittent Or Incorrect

51

2

Voltage Above Normal, Or Shorted To High Source

51

3

Voltage Below Normal, Or Shorted To Low Source

51

4

Abnormal Rate Of Change

51

10

Out Of Calibration

51

13

Vehicle Speed
Sensor

Data Valid But Above Normal Operational Range - Most
Severe Level

84

0

Data Valid But Below Normal Operational Range - Most
Severe Level

84

1

Data Erratic, Intermittent Or Incorrect

84

2

Voltage Above Normal, Or Shorted To High Source

84

3

Voltage Below Normal, Or Shorted To Low Source

84

4

Abnormal Frequency Or Pulse Width Or Period

84

8

Abnormal Update Rate

84

9

Abnormal Rate Of Change

84

10

Bad Intelligent Device Or Component

84

12

Received Network Data In Error

84

19

Accelerator
Position 1

Data Erratic, Intermittent Or Incorrect

91

2

Voltage Above Normal, Or Shorted To High Source

91

3

Voltage Below Normal, Or Shorted To Low Source

91

4

Manifold Absolute
Pressure Sensor

Data Erratic, Intermittent Or Incorrect

102

2

Voltage Above Normal, Or Shorted To High Source

102

3

Voltage Below Normal, Or Shorted To Low Source

102

4

Mechanical System Not Responding Or Out Of Adjustment

102

7

Abnormal Rate Of Change

102

10