Installation and Configuration

Selecting Normal or Low line voltage range

To convert from Normal to Low voltage operation:

• Remove the Yellow and Black transformer leads from the Power Entry Module.

• Cover these leads with insulation (electrical tape) to prevent contact with the chassis or

other components.

• Connect the unused Blue and Red leads, below. It is imperative that the leads go to the

correct positions or damage to the HDX may result. Re-assemble the HDX in reverse
order to complete the conversion.

To convert back to Normal voltage, reverse the above procedure.

IMPORTANT

Be sure to remove all external connections from the HDX including the
power cord before attempting these changes.

100/200V

120/240V

D

White

White

C

Orange

Orange

B

Blue

Yellow

A

Red

Black