Navigating the local control panel menu, Local control panel menu structure – Grass Valley Kaleido-MX (1RU) v.7.80 User Manual
Page 41

27
Kaleido-MX (1RU)
Hardware Description & Installation Manual
The panel is assigned to operate any card in the frame by pressing the Select button on the
front edge of that card. The Status LED on the selected card will then be blinking orange.
Press the CONTROLLER button on the control panel to select the controller card itself.
Navigating the Local Control Panel Menu
The Kaleido-MX has operating parameters which may be adjusted locally at the controller
card interface. Press the Select button on the front edge of a Kaleido-MX input or output card
(see
, on page 22) to assign the local control panel to operate
the card. The local control panel displays a menu that can be navigated using the four
buttons located next to the display. The functionality of the buttons is as follows:
If no controls are operated for 30 seconds, the controller reverts to its normal standby
status, and the selected card’s Status LED reverts to its normal operating mode. If a
parameter was changed on the card but not submitted (SEL was not pressed) and the
30 second timeout occurs, the parameters will be confirmed as if the SEL button had been
pressed.
Local Control Panel Menu Structure
Where applicable, default values are underlined.
[+] and [-] Used for menu navigation and value modification.
SEL
Gives access to the next menu level. When a parameter value is shown, pressing this
button once enables modification of the value using the [+] and [-] buttons;
pressing a second time confirms the new value.
ESC
Cancels the effect of parameter value changes that have not been confirmed;
pressing ESC causes the parameter to revert to its former value.
Pressing ESC moves the user back up to the previous menu level. At the main menu,
ESC does not exit the menu system. To exit, press the Select button on the front
edge of the card being controlled.
Kaleido-MX output card local menu
STATUS
{CARD STATUS}**
{CARD VERSION}**
RESOLUTION
HEAD1
{List of resolutions;* = current}**
HEAD2
{List of resolutions;* = current}**
{LINK STATE}**
FANS
{CPU FAN STATUS}**
{FPGA FAN STATUS}**
NETWORK SETTINGS
FRAME IP ADDRESS EDIT ###.###.###.###
NETMASK EDIT
###.###.###.###
DEFAULT GW EDIT
###.###.###.###
LINK MODE EDIT
Auto-negotiate
100Mbps half-duplex