beautypg.com

Power connections, 120 vac, 240 vac – Grass Valley 8900 Frames Gecko 2007 User Manual

Page 34

background image

34

Gecko Frames Instruction Manual

Section 3 — Power Up

Power Connections

There are two types of power cords supplied with the 8900 Series frames
for 120 V and 240 V operation. Line voltage selection is not required for this
power supply. Optional redundant power supplies are also shipped with
both types of power cord.

120 VAC

This cord has a molded grounding plug at one end and a molded grounded
receptacle at the other end. Conductors are color-coded white (neutral),
black (line), and green or green/yellow (ground).

240 VAC

This cord has a molded grounding receptacle at one end and stripped con-
ductors at the other end. Conductors are color-coded light blue (neutral),
brown (line), and green/yellow (ground).

For each power supply installed, AC power is fed through a line cord to a
socket (J1 and J2) on the rear of the frame (

Figure 16

).

Figure 16. AC Power Connectors

Note

To maintain maximum redundant power, ensure that each power supply cord
is plugged into a separate branch circuit.

0636 -05r1

J1

J2

RS232

ETHERNET

This manual is related to the following products: