beautypg.com

Frame alarm example, To frame alarm example, For using the port in – Grass Valley 8900 Frames Gecko 2007 User Manual

Page 32

background image

32

Gecko Frames Instruction Manual

Section 2 — Installation

Frame Alarm Example

Refer to

Figure 14

for an example of a typical alarm schematic using pins 8

and 9 of the RS-232 port.

Figure 14. Typical Alarm Schematic for Frame Alarm

The impedance between the pins 8 and 9 of the RS-232 connector can be in
one of two states:

Open – less than 100 μA of current will flow with 5 volts across the pins,
and

Closed – less than 0.2 V will appear from pin 8 to pin 9 with 20 mA of
current flowing.

There are three operational conditions (capability is module dependent,
refer to specific module instruction manual):

Open – no faults,

Closed – there is an internal fault, and

Pulsing – there is a missing or invalid signal on one or more of the mod-
ules.

+5V

4.7 k

Ω

4.7 k

Ω

330

Ω

470

Ω

Alarm
LED

2N4126
(or equivalent)

RS-232 Pin 8

RS-232 Pin 9

This manual is related to the following products: