Frame alarm example, To frame alarm example, For using the port in – Grass Valley 8900 Frames Gecko 2007 User Manual
Page 32
32
Gecko Frames Instruction Manual
Section 2 — Installation
Frame Alarm Example
Refer to
for an example of a typical alarm schematic using pins 8
and 9 of the RS-232 port.
Figure 14. Typical Alarm Schematic for Frame Alarm
The impedance between the pins 8 and 9 of the RS-232 connector can be in
one of two states:
•
Open – less than 100 μA of current will flow with 5 volts across the pins,
and
•
Closed – less than 0.2 V will appear from pin 8 to pin 9 with 20 mA of
current flowing.
There are three operational conditions (capability is module dependent,
refer to specific module instruction manual):
•
Open – no faults,
•
Closed – there is an internal fault, and
•
Pulsing – there is a missing or invalid signal on one or more of the mod-
ules.
+5V
4.7 k
Ω
4.7 k
Ω
330
Ω
470
Ω
Alarm
LED
2N4126
(or equivalent)
RS-232 Pin 8
RS-232 Pin 9