Grass Valley RCP2050 User Manual
Page 24

20
CopperHead RCP 2050 Features
Function buttons
Buttons
Description
11. ON/OFF
OCU on/off.
Toggles the OCU on/off. On power-up, the LED flashes indicating
that the OCU is acquiring comms with the camera. The LED attains
steady state when comms are correctly established and the last
saved scene file is recalled and applied.
12 CALL
Performs call function with the camera. Usually this means
flashing the tally lights on the camera and the viewfinder. This can
vary with camera type or camera settings.
13. VTR
Switches the scene file and MODE buttons to VTR mode - on or off
as applicable.
14. BARS
Toggles camera color bars on and off.
15. MON
Switches on or off the color monitor On Screen Display characters
(OSD).
16. ENGR
Switches on and off the Engineering setup menus.
17. MENU
Switches the camera menu on and off if applicable.
When on, the rotary encoder is enabled for item selection and
adjustment.
18. GAIN
Increments or decrements the fixed gain value shown on the OSD.
19. SHUTTER
Increments or decrements the fixed shutter value shown on the
OSD. To turn shutter OFF, hold down the DOWN button for two
seconds.
20. BALANCE
20A.COLOR Enables variable adjustment of the 4 color balance controls.
20B. AUTO2 Applies auto balance 2.
20C. AUTO1 Applies auto balance 1.
20D. PRESET Sets the camera internal preset color balance levels.
20E. AWB Performs an auto-white balance.
20F. ABB Performs an auto-black balance.
21. SCENE FILE 1 - 4
Saves and recalls 5 complete OCU settings. On power-up the last
saved scene file is recalled.
• To save a file - press and hold the button to save for
approximately 2.5 seconds until all four scene file buttons are
illuminated. On release of the button the single stored scene file
button then illuminates.
• To recall a file - press a button momentarily for less than 2
seconds. The selected file button then illuminates.
De-selecting a scene file (pressing illuminated button - all files off )
recalls the user default file which can be a starting point for
setting a new scene file. This file is stored by pressing button 1
followed by button 4 within 2.5 seconds. Factory default settings
can be recalled by pressing 'CALL' followed by 'TEST' buttons.