TFT/LCD Screen adjustments

Fig. 2-5: Engineering Menu, Page 3

Page 3 of the Engineering menu allows you to control four aspects of the built-in optional
LCD/TFT screen. Each has a range of 0 to 255. Default is 128

Brightness: adjust from 0 to 255. Push the Rotary Encoder to select.

Contrast : adjust from 0 to 255. Push the Rotary Encoder to select.

Colour: adjust from 0 to 255. Push the Rotary Encoder to select.

Tint: adjust from 0 to 255. Push the Rotary Encoder to select.

Test LEDs: when selected, the test will start by illuminating tally (Red and Green), and

then illuminate the buttons in groups and end with the blue leds. The OCU will then
revert to normal operation.

Note that the SHUTTER

▲▼

and GAIN

▲▼

buttons do not illuminate.

Note:

• Normally the joystick iris control range is set so that it matches the

camera iris range, but it is possible to adjust the settings MIN & MAX
so that a large movement of the joystick controls a small camera iris
movement for fine control. Simply adjust the rotary encoder for lens
iris positions that are required relative to the joystick position.

• Some Sony camera models allow iris adjustment across a range

between approximately 038 minimum and 110.

• Always adjust the minimum control position first.