Serial Interface

RS-232C, 9600 bps, 8-bit, parity none, stop bit = 1 bit

„

Command List

2

List of Commands

2-1

Remote Control Function

PL

Start playback if the current mode is not playback (encode)
Format: “PL”
Status report: Completion message (“R”)

RC

Start record if the current mode is not record (decode)
Format: “RC”
Status report: Completion message (“R”)

SO

If the current mode is playback (encode), stop playback and
start record
Format: “SO”
Status report: Completion message (“R”)

?P

Check the current operation mode
Format: “?P”
Status report: “P02”: ADVC-HDM1 starting or mode in transi-

tion
“P04”: Playback (encode)
“P14”: Record (decode)

TC

Change the input time code setting for encoding to VITC or
LTC
Format:

“(Integer) TC”
“1TC” VITC
“2TC” LTC

Status report: Completion message (“R”)

E06: Command argument error (integer is

neither 1 nor 2)

When the input time code is changed during decode opera-
tion, the changed setting is enabled from the next encode
operation.

?T

Check the input time code setting of the current encoding
Format: “?T”
Status report: “1”: VITC

“2”: LTC

05_Appendix_ADVC_HDM1_EN.fm Page 21 Wednesday, December 20, 2006 12:37 PM