Grass Valley 2041EDA User Manual
Page 11

2041EDA Instruction Manual
11
Power Up
A red FAULT LED indicates an error situation and, when noted with the
other indicator LEDs, can indicate a specific problem area.
describes
signal output and LED indications for the various input/reference combi-
nations.
provides the possible input and output conditions that result from
different input signals and conditions.
Table 1. Indicator LEDs and Conditions Indicated
LED
Indication
Condition
Off Normal
operation
FAULT (red)
On continuously
Module has detected internal fault
Long flash
No input signal
COMM (yellow)
Off
No activity on frame communication bus
Long flash
Location Command received by the module from a remote control system
Short flash
Activity present on the frame communication bus
CONF (yellow)
Off
Module is in normal operating mode
On continuously
Module is initializing, changing operating modes or updating firmware
PWR (green)
Off
No power to module or module’s DC/DC converter failed
On continuously
Normal operation, module is powered
SIG_PRES
Off
Indicates no signal carrier present
On continuously
Indicates signal carrier present
SIG (rear view)
Off
Indicates no signal carrier present
On continuously
Indicates signal carrier present
Table 2. Input and Output Conditions
Input Condition
Output Condition
Serial Digital Component (SDI)
Serial Digital Component (SDI)
HD Digital Component (SDI)
HD Digital Component (SDI)
Other carrier
Other carrier
No input
Muted
Cable exceeding 200 meters
Muted