Mounting the gateway to the rack – H3C Technologies H3C SecPath M9000 Series User Manual

Page 8

background image

5

Mounting the gateway to the rack

CAUTION:

Do not hold the handle of the fan tray or power module, or the handle on the rear of the chassis, or the air
vents of chassis. Any attempt to carry the gateway with these parts may cause equipment damage or even

bodily injury.

To mount the gateway to the rack:

1.

Move the chassis to face the rear of the chassis towards the front of the rack.

2.

Use at least two people to lift the gateway by using the handles of the chassis, place the gateway
on the slide rails or rack shelf, and slide the gateway along the slide rails until the mounting

brackets on the gateway touch the front rack posts.
The handle of an M9006 is located at the top of chassis. The handles of an M9010 or M9014 are
located at the two sides of the chassis.

3.

Attach the chassis to the rack with mounting screws.

Figure 6 Installing the chassis to the rack (M9006)

If the mounting holes in the mounting brackets cannot align with the cage nuts on the rack, verify that the
bottom edge of the slide rail or rack shelf aligns with the middle of the narrower metal area between

holes and that the cage nuts are installed in the correct holes.