Verifying the configuration – H3C Technologies H3C S12500-X Series Switches User Manual
Page 19

13
[Switch] vlan 4092
[Switch-vlan4092] port ten-gigabitethernet 1/0/1
[Switch-vlan4092] quit
[Switch] vlan 4094
[Switch-vlan4092] port ten-gigabitethernet 1/0/2
[Switch-vlan4092] quit
# Create OpenFlow instance 1 and associate VLANs with it.
[Switch] openflow instance 1
[Switch-of-inst-1] classification vlan 4092 mask 4093 loosen
# Specify a controller for the OpenFlow instance and activate the instance.
[Switch-of-inst-1] controller 1 address ip 192.168.49.49
[Switch-of-inst-1] active instance
Verifying the configuration
# Display the detailed information for OpenFlow instance 1.
[Switch-of-inst-1] display openflow summary
Instance 1 information:
Configuration information:
Description : --
Active status : Active
Inactive configuration:
None
Active configuration:
Classification VLAN, loosen mode, total VLANs(2)
4092, 4094
In-band management VLAN, total VLANs(0)
Empty VLAN
Connect mode: Multiple
Mac address learning: Enabled
Flow table:
Table ID(type): 0(Extensibility), count: 0
Flow-entry max-limit: 65535
Default table-miss: Drop
Forbidden port: None
Datapath ID: 0x00010cda415e232e
Port information:
Ten-GigabitEthernet1/0/1
Ten-GigabitEthernet1/0/2
Active channel information:
Failopen mode: secure