ADJUSTING PARAMETERS FROM THE FRONT PANEL
Use the
Mode, Right Arrow, and Left Arrow buttons to select and adjust
parameters from the front panel.
Pressing the
Mode button activates the front panel for editing and tabs between
each section of editable parameters.
Pressing the
Right Arrow or Left Arrow advances the selection within a given
section of parameters, or increases (Right Arrow) or decreases (Left Arrow) the
value of a selected parameter.
The LED of an edited parameter will blink for 15 seconds, after which time its value is
stored in memory. If power is interrupted before this 15 second timeout period has
elapsed, the edited state will not be not saved.
The LED indicators will report the following:
• Std (Standard) select – currently selected video output standard
blinks.
• Video – currently selected video pattern (or pattern group) output
blinks.
• Slate on/off – blinks quickly when ID slate is enabled, slowly when
disabled.
• Tone on/off – blinks quickly when tone is enabled, slowly when
disabled.
• HD Sync select – currently selected HD Tri Level Sync format
blinks.
The controls and their indicators are described below:
Std (Standard)
This control selects the video output standard with the following choices:
NTSC – 525 NTSC standard
PAL – 625 PAL standard
Video
This control selects the video test pattern with the following choices:
• Black choices:,
Black, Flat 20%, or Flat 80%.
• Bar choices: 75% Bars, 100% Bars, or SMPTE Bars.
• Sweep choices: Sweep, Mono Sweep, Multi Burst, or Mono Burst.
• User choices – This pattern can be specified in the Test Pattern menu,
providing over eight additional patterns (
Pathological, Pulse and Bar,
Ramp, Digital Blanking, Analog Blanking, Interlace, Crosshatch,
and
Unit Circle).
Mono Sweep and Mono Burst are recommended for analog applications and Sweep
and Multi Burst for SDI video applications.
NOTE
: