Config Menu
Use the Config menu shown below to set the following parameters:

• Standard – select the output standard for SDI and composite video. This

pulldown lets you chose between:

NTSC (525) and PAL (625).

• HD Standard – select the HD Tri Level Sync standard. This pulldown lets

you choose between:

1080i, 720p, 1080p, or 1080sF.

• Setup – turn Setup On or Off for 525 60Hz signals.
• Slate Text - the contents of this text field will be displayed in the ID Slate.

Enter up to 19 characters.

• Dig Ref Level – select the digital audio reference level. This pulldown lets

you choose between:

-18dBFS or -20dBFS.

• Analog Ref Level – select the analog audio reference level. This pulldown

lets you choose between:

-10 dB, -6 dB, -4 dB, 0 dB, or +4 dB.

• TLS Framerate – this control allows selection of the Tri Level Sync frame

rate output between

23.98/50/59.94 Hz and 24/30/60 Hz. Refer to the

discussion of this functionality in the

FUNCTIONAL DESCRIPTION at

the front of this document.

• Freq Adjust – this control temporarily enables the Freq Adjust control.

When this control is set to

Allowed the user has 20 seconds to begin

adjusting the internal clock frequency, after 20 seconds this

Freq Adjust

is disabled.

• Freq Adjust – this control allows the internal timing source to be adjusted.

See the

ADJUSTMENTS section near the end of this manual for more

details and the adjustment procedure.