Timing Menu

Timing adjustments can be made when the Frame Sync function is enabled on
the unit.

The Timing menu provides the following controls:

Ver Time – adjusts the vertical timing of the signal in +/- 625 line incre-
ments relative to the reference input when Frame Sync is enabled (on).
There is no front panel control or indication of this setting.

Hor Time – adjusts the horizontal timing of the signal in +/- 1715 clock
increments relative to the input reference when Frame Sync is enabled
(on).There is no front panel control or indication of this setting.

V Blanking – set vertical blanking to Wide (PAL Lines 1-22 and NTSC
Lines 1-20) or Narrow (PAL Lines 1-6 and NTSC Lines 1-9). There is no
front panel control or indication of this setting.

Frame Sync – turns the Frame Sync function on or off with the menu
pulldown.