6.6.2

USER PORT CONFIGURATION

6.6.2.1

V35 USER PORT

Data Rate: The data rate can only be set by the ‘master’ unit and is set in increments of 64kbps.
The data rate is set by entering the desired value of N from 1 (64kbps) to 36 (2304kbps). The
default value of N is 32.

Timing Options: The timing options can only be set by the ‘master’ unit.

OM25 Thu 01 Jan 1970

Configuration > User Port

Urgent Alarm:On Non-Urgent Alarm:Off

Subsystem: Master

Port Type: OM25-V35

Rate (nx64): <32> Enable Loops:

Timing Control Lines:

Internal: (*) 106 Clamp On:

External: ( ) 107 Clamp On:

Loop: ( ) 109 Clamp On:

End-to-end Signalling

Press Return to Accept or Escape to Cancel

F1 Help F3 Previous Menu F4 Main Menu F7 Previous Subsystem

F8 Next Subsystem