Technical data – ARAG DIGIWOLF - Battery powered version User Manual
Page 20
20
Data
Min.
Max.
Default
UoM
Notes
Calibration
Manual calibration
1
50,000
600
--
--
Flowrate alarms
Min. flowrate alarm
0.1
99999.9
OFF
l/min.
The alarm can be deactivated
setting the value "OFF"
Max. flowrate alarm
0.1
999999.9
OFF
l/min.
The alarm can be deactivated
setting the value "OFF"
Display
Brightness
0%
100%
50%
%
--
Contrast
0%
100%
50%
%
--
Energy
saving
Backlight
shut-off
1 sec.
300 sec.
30 sec.
sec.
Display
shut-off
1 min.
120 min.
15 min.
min.
Options
Language
-
-
English
-
Language settings: Italiano, English, Español,
Português, Français, Deutsch, Cesky, Polski,
ニホン
, Русский, Magyar.
Rate units of
measurement
-
-
l/min.
-
Units of measurement settings: l/min, GPM,
m
3
/h
Volume units of
measurement
-
-
litres
-
Units of measurement settings: l, gal, m
3
7
TECHNICAl DATA
Description
DigiWolf
Power supply
2 AA batteries type LR6 (alkaline) or FR6 (Li-Fe S2)
Max. absorption
40 mA (100% backlight)
4.7uA (standby)
Working temperature
0 °C ÷ 50 °C
+32 °F ÷ +122 °F
Storage temperature
0 °C ÷ 50 °C / +32 °F ÷ +122 °F (inserted batteries)
-30 °C ÷ 80 °C / -22 °F ÷ +176 °F (without batteries)
Weight (without batteries)
680 ÷ 750 g (depending on the type)
8
DISPOSAl AT THE END OF SERvICE
Dispose of the system in compliance with the established legislation in the country of use.
Tab. 5
Tab. 6
TECHNICAL DATA