Setup, Bd a – ARAG DIGIWOLF - Battery powered version User Manual
Page 12
12
4.2
Flowrate alarms
Set the minimum and maximum values beyond which the display must show an alarm message.
Flowrate alarms
Min flow alarm
Max flow alarm
6.00/min
1) Access Flowrate alarms menu (Setup menu > Flowrate alarms).
Min. and max. flowrate alarms setting is done in the same way.
Under the selected item, the currently set value will be displayed.
Press
OK
to access modification of the selected item.
Min flow alarm
Min value
Max value
0.1
99999.9
OFF
o
2) To activate the alarm, press
and
at the same time until the message
OFF disappears and flowrate alarm value is displayed.
Carry out the same procedure to deactivate flowrate alarm again.
Min flow alarm
Min value
Max value
C
0.1
99999.9
B
D
A
0040.0
0
l/min
o
3) Set flowrate alarm value:
A)
Press to toggle from one digit to another
B)
Press in succession to modify the value of the digit highlighted by the cursor
C)
Press to save changes or
D)
Press to exit current page without confirming changes.
4.3 Display
Adjust display brightness and contrast.
Display
Luminosità
Contrasto
50%
Access display menu (Setup menu > Display).
Brightness and contrast adjustment is done in the same way.
Under the selected item, the currently set value will be displayed.
Press
OK
to access modification of the selected item.
Luminosità
50%
1
2
2
1) Set the value using the key
. Each time it is pressed, the value will increa-
se by 10% until reaching 100%, and then starts back from 0.
2) Press
OK
to save, or
ESC
to exit without saving.
The brightness value affects battery life: the higher the value, the shor-
ter the battery life.
Fig. 22
Fig. 23
Fig. 25
Fig. 24
Fig. 26