ARAG BRAVO130 User Manual
Page 23

23
9.1.1
Two-sensor configurations
The following information will appear on the display:
D
A
B
C
Fig. 16
A • the distribution value, the instantaneous
speed or the pressure value measured by the
transducer; the value displayed will depend on how
the computer was programmed during installation.
B and C • data relative to the activated sensors
(
B for the left side and C for the right side of the
tractor).
D • the number of the active field.
2 SENSORS - 2 SPRAYING BOOMS
Fig. 17
2 SENSORS - 4 SPRAYING BOOMS
Fig. 18
• The
key activates the sensor installed on the left side of the tractor:
to activate sensor
S1
, which controls the opening and closing of
R1
spraying boom, press the
key.
• The
key activates the sensor installed on the right side of the tractor: to activate sensor
S2
,
which controls the opening and closing of
R2
spraying boom, press the
key.
The symbol displays when the LH sensor is active.
The symbol displays when the RH sensor is active.
When all the sensors are enabled, the display will show the following information:
D
A
B
C
Fig. 19
A • the distribution value, the instantaneous
speed or the pressure value measured by the
transducer; the value displayed will depend on how
the computer was programmed during installation.
B and C • data relative to the activated sensors
(
B for the left side and C for the right side of the
tractor): the value between parentheses is the
number of the active sensor).
D • the number of the active field.
When
displays in place of the sensor number, this indicates that the sensor in
question has detected a tree: when one or more booms are in line with the plants, and
if the valves have been enabled (section valve switches up), treatment is initiated.