AML M5900 Portable Batch Data Terminal User Manual
Page 38
31
CODABAR
Send Start / Stop
ON
Transmit the Codabar start/stop characters.
OFF * Do not transmit the Codabar start/stop characters.
CLSI Formatting
ON
The reader will insert a blank after the 1st, 5th, and 10th characters of a
14-character Codabar label. The label length does not include the start
and stop characters.
OFF * Disable CLSI formatting.
CLSI Check Digit
ON
Enable the CLSI check digit. When this option is enabled, all fourteen
digit numeric bar codes must contain a valid check digit.
OFF* Disable the CLSI check digit. Check digit verification will not be
performed.
CODE 128