LSC100 LIGHT SEQUENCE COMMANDER
The LSC100 Light Sequence Commander includes an
engine auto-start control, with a light circuit controller.
It provides complete automatic light tower operation
once the machine is set up on the jobsite. This control
can be equipped with an optional seven-day
programmable timer.
1
Auto/
Manual
Switch to AUTO to enable
auto-start. Switch to MANUAL to
manually start the engine. Switch
to the center OFF position to start
the shutdown sequence. The OFF
position is also used to reset the
controller.
2
Power
switch
Switch to ON to start the engine
when the AUTO/MANUAL switch
is set to MANUAL, or to enable
auto-start when set to AUTO.
Switch to OFF to start the
shutdown sequence.
3
Alarm
indicator
Flashes red to indicate a low fuel
level, low oil pressure, high water
temperature, or engine start
failure. The engine will shut down
if running, or will not start.
1
2
3 4
5 6 7
4
Glow Plug
indicator
Lights red to indicate when the
glow plug is turned on.
5
Crank
indicator
Lights yellow to indicate that the
engine is cranking to start.
6
Fuel/Run
indicator
Lights green to indicate sufficient
fuel in the tank to run the engine.
7
Power
indicator
Lights red to indicate that power
is being provided to the LSC100
panel.