Object count analysis property settings – ACTi IVS Server 1 V2.02.06 User Manual
Page 35

ACT
i IVS Server 1 User’s Manual
count the objects that cross over this line by dragging your cursor from a starting point
to an end point.
4.
Once completed, you will see the line and the labels that will be used to show the
number of objects entering (
In
) and exiting (
Out
) the scene. To re-draw the line or
reverse the locations for
In
and
Out
, simply right-click the line and select
“reverse”
or
“remove”
.
5.
Click
“Start Counting”
to start running your analysis.
\\
Object Count Analysis Property Settings
Property
Description
Default
Enable
Enables
People Counting
algorithm.
Disabled
Object
Height
Depending on the distance between your camera device and
the ground, the perceived size of objects passing by will
change (For example: the farther the device is, the smaller
objects will appear).
Object Height
allows the user to
determine the height (1-60 pixels) of the
Object Size
Reference Frame
(found in the bottom left corner of the
Live
12
3
2
5
Important Notice
For the
Object Count
algorithm to work properly, make sure the camera from which you are
obtaining the video is located above the scene of interest.
(Optional)
4
1