General interface specifications for all mrds – Westermo MRD-315 User Manual
Page 14
14
6623-2250
General interface specifications for all MRDs
RS-232
Electrical specification
EIA RS-232
Data rate
300 bit/s – 115.2 kbit/s
Data format
7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits
Protocol
Transparent, optimised by packing algorithm
Circuit type
SELV
Transmission range
15 m/49 ft
Connection
9 pin D-sub female
Shielded cable
Not required
Conductive housing
Yes
Number of ports
1
Ethernet TX
Electrical specification
IEEE std 802.3. 2005 Edition
Data rate
10 Mbit/s, 100 Mbit/s, manual or auto
Duplex
Full or half, manual or auto
Circuit type
SELV
Transmission range
100 m/328 ft
Isolation to
All other
Connection
RJ-45 auto MDI/MDIX
Shielded cable
Not required, except when installed in Railway applications as signalling
and telecommunications apparatus and located close to rails.*
Conductive housing
Yes
Number of ports
2
* To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m
boundary to the rails and connected to this port. The cable shield should be properly connected (360º) to an
earthing point within 1 m from this port. This earthing point should have a low impedance connection to the
conductive enclosure of the apparatus cabinet, or similar, where the unit is built-in. This conductive enclosure
should be connected to the earthing system of an installation and may be directly connected to the protective
earth.