Type tests and environmental conditions – Westermo MRD-315 User Manual
Page 10
10
6623-2250
Type tests and environmental conditions
Phenomena
Test
Description
Test levels
ESD
EN 61000-4-2
Enclosure contact
± 6 kV (crit A)*
Enclosure air
± 8 kV (crit A)*
RF field AM modulated
IEC 61000-4-3
Enclosure
10 V/m (crit A)*
(80 – 2700 MHz)
Fast transient
EN 61000-4-4
Signal ports
± 1 kV (crit A)*
Power ports
± 2 kV (crit A)*
Surge
EN 61000-4-5
Ethernet ports
± 1 kV (direct) (crit B)*
Power ports
± 0.5 kV (line to earth) (crit B)*
± 0.5 kV (line to line) (crit B)*
RF conducted
EN 61000-4-6
All ports
10 V/m, (crit A) *
(0.15 – 80 MHz)
Radiated emission
EN 55022
Enclosure
Class B
Conducted emission
EN 55022
DC power ports
Class B
Ethernet ports
Class B
Temperature
Operating
–40 to +70ºC
Storage & Transport
–40 to +85ºC
Humidity
Operating
0 to 90% relative humidity non
condensing.
Storage & Transport
0 to 90% relative humidity non
condensing.
Altitude
Operating
2000 m/70 kPa
MTBF
MIL-217-F
MRD-315
825 759 hours
MRD-355
689 933 hours
MRD-455
689 933 hours
Service life
Operating
10 year
Dimension W x H x D
53 x 103 x 134 mm
Weight
0.40 kg
Degree of protection
IEC 529
Enclosure
IP 40
Cooling
Convection
Mounting
Horizontal on 35 mm DIN-rail
*crit A = no effect, crit B = restart without user intervention