6640-2205

Type tests and environmental conditions

Environmental phenomena Basic standard

Description

Test levels

EMC
ESD

EN 61000-4-2

Enclosure contact  ± 6 kV
Enclosure air

± 8 kV

RF field AM modulated

EN 61000-4-3

Enclosure

10 V/m 80 – 800 och 1000 – 2100 MHz 
20 V/m   800 – 1000 MHz 
  5 V/m 2100 – 2500 MHz 
  1 V/m 2500 – 2700 MHz

Fast transient

EN 61000-4-4

Signal ports

± 2 kV

Power ports

± 2 kV

Surge

EN 61000-4-5

Signal ports

± 2 kV line to earth, ± 2 kV potential difference

Power ports

± 2 kV line to earth, ± 2 kV line to line

RF conducted

EN 61000-4-6

Signal ports

10 V 80% AM (1 kHz), 0.15 – 80 MHz

Power ports

10 V 80% AM (1 kHz), 0.15 – 80 MHz

Power frequency magnetic field EN 61000-4-8

Enclosure

1000 A/m, 50 Hz

Pulse magnetic field

EN 61000-4-9

Enclosure

300 A/m 

Voltage dips and interruption

EN 61000-4-29

DC power ports

Voltage interruption - 3 x 30 s within 5 minutes: 
19V to 0 V & 62.4 V to 0V 
Power supply variation - 3 x 1 minute 
30% increase and 25% reduction

Radiated emission

EN 55022

Enclosure

Class B

FCC part 15

Class B

IEC 60945

Complying with the limit line

Conducted emission

EN 55022

Signal ports

Class B

EN 55022

DC power ports

Class B

IEC 60945

Complying with the limit line

Dielectric strength

EN 60950-1

Signal port to 
other isolated 
ports

1.5 kVrms 50 Hz 1 min

Power port to 
other isolated 
ports

1.5 kVrms 50 Hz 1 min

Environmental

Temperature

Operating

 –40 to +70ºC 

Storage & 
Transport

–50 to + 85ºC

Humidity

Operating

5 to 95% relative humidity

Storage & 
Transport

5 to 95% relative humidity

Altitude

Operating

2 000 m / 70 kPa

Service life

Operating

10 year

Vibration

IEC 60068-2-6

Operating

1 mm, 3 – 13.2 Hz 
0.7 g, 13.2 – 100 Hz 
1.5 g, 5.5 – 30 Hz

0.42 mm, 30 – 50 Hz 
4.2 g, 50 – 500 Hz

IEC 60068-2-64

Operating

0.23 g, 3 – 2000 Hz

Shock

IEC 60068-2-27

Operating

All directions:   2 g, 11 ms
Z-axis: 

30 g, 11 ms

Bump

IEC 60068-2-29

Operating

2 g, 11ms

Packaging

Enclosure

UL 94

Aluminium

Flammability class V-1

Dimension W x H x D 
With connectors

52.5 x 100 x 101 mm 
52.5 x 119 x 101 mm

Weight

0.6 kg

Degree of protection

IEC 529

Enclosure

IP 40

Cooling

Convection

Mounting

Horizontal on 35 mm DIN-rail