6640-2205
Type tests and environmental conditions
Environmental phenomena Basic standard
Description
Test levels
EMC
ESD
EN 61000-4-2
Enclosure contact ± 6 kV
Enclosure air
± 8 kV
RF field AM modulated
EN 61000-4-3
Enclosure
10 V/m 80 – 800 och 1000 – 2100 MHz
20 V/m 800 – 1000 MHz
5 V/m 2100 – 2500 MHz
1 V/m 2500 – 2700 MHz
Fast transient
EN 61000-4-4
Signal ports
± 2 kV
Power ports
± 2 kV
Surge
EN 61000-4-5
Signal ports
± 2 kV line to earth, ± 2 kV potential difference
Power ports
± 2 kV line to earth, ± 2 kV line to line
RF conducted
EN 61000-4-6
Signal ports
10 V 80% AM (1 kHz), 0.15 – 80 MHz
Power ports
10 V 80% AM (1 kHz), 0.15 – 80 MHz
Power frequency magnetic field EN 61000-4-8
Enclosure
1000 A/m, 50 Hz
Pulse magnetic field
EN 61000-4-9
Enclosure
300 A/m
Voltage dips and interruption
EN 61000-4-29
DC power ports
Voltage interruption - 3 x 30 s within 5 minutes:
19V to 0 V & 62.4 V to 0V
Power supply variation - 3 x 1 minute
30% increase and 25% reduction
Radiated emission
EN 55022
Enclosure
Class B
FCC part 15
Class B
IEC 60945
Complying with the limit line
Conducted emission
EN 55022
Signal ports
Class B
EN 55022
DC power ports
Class B
IEC 60945
Complying with the limit line
Dielectric strength
EN 60950-1
Signal port to
other isolated
ports
1.5 kVrms 50 Hz 1 min
Power port to
other isolated
ports
1.5 kVrms 50 Hz 1 min
Environmental
Temperature
Operating
–40 to +70ºC
Storage &
Transport
–50 to + 85ºC
Humidity
Operating
5 to 95% relative humidity
Storage &
Transport
5 to 95% relative humidity
Altitude
Operating
2 000 m / 70 kPa
Service life
Operating
10 year
Vibration
IEC 60068-2-6
Operating
1 mm, 3 – 13.2 Hz
0.7 g, 13.2 – 100 Hz
1.5 g, 5.5 – 30 Hz
0.42 mm, 30 – 50 Hz
4.2 g, 50 – 500 Hz
IEC 60068-2-64
Operating
0.23 g, 3 – 2000 Hz
Shock
IEC 60068-2-27
Operating
All directions: 2 g, 11 ms
Z-axis:
30 g, 11 ms
Bump
IEC 60068-2-29
Operating
2 g, 11ms
Packaging
Enclosure
UL 94
Aluminium
Flammability class V-1
Dimension W x H x D
With connectors
52.5 x 100 x 101 mm
52.5 x 119 x 101 mm
Weight
0.6 kg
Degree of protection
IEC 529
Enclosure
IP 40
Cooling
Convection
Mounting
Horizontal on 35 mm DIN-rail