6640-2205
Ethernet SFP pluggable connections (FX or TX)
Electrical specification
IEEE std 802.3. 2005 Edition
Data rate
100 Mbit/s, 1000 Mbit/s manual or auto
Duplex
Full or half, manual or auto
Transmission range
Depending on tranceiver
Connection
FX connectors:LC
Copper connectors (CX) can not be used in combination
with FRNT
Shielded cable
Not required
Conductive housing
Isolated to all other circuits
Number of ports
1 or 2
Status relay
Contact resistance
Max 30 Ω
Isolation to
All other
Connection
Detachable screw terminal
Connector size
0.2 – 2.5 mm
2
(AWG 24 – 12)
Maximum voltage / current
60 VDC / 80 mA