beautypg.com

Westermo Lynx 100 User Manual

Page 20

background image

20

6640-2205

Setup examples:

1. FRNT ring using fibre cables
The rules are as follows:

The switches should be connected by switch port 7 to 8, 7  

• 

to 8, 7 to 8... throughout the ring
Define switch port 7 as FRNT port 1 and switch port 8  

• 

as FRNT port 2 on all switches.
One switch in the ring must be configured as "Focal Point"

• 

2. FRNT ring using copper cables
The rules are as follows:

The switches should be connected by switch port 5 to 6, 5  

• 

to 6, 5 to 6... throughout the ring
Define switch port 5 as FRNT port 1 and switch port 6  

• 

as FRNT port 2 on all switches.
One switch in the ring must be configured as "Focal Point"

• 

3. FRNT ring using fibre and copper cables
The rules are as follows:

The switches should be connected by switch port 7 to port 8 where you are using 

• 

fibre cable and switch port 5 to 6 where you are using copper cable.
Define switch port 7 as FRNT port 1 and switch port 8 as FRNT port 2 on all 

• 

switches where you are using fibre cable. Define switch port 5 as FRNT port 1 and 
switch port 6 as FRNT port 2 on all switches where you are using copper cable.
One switch in the ring must be configured as "Focal Point" 

• 

This manual is related to the following products: