Westermo Lynx 100 User Manual
Page 20
20
6640-2205
Setup examples:
1. FRNT ring using fibre cables
The rules are as follows:
The switches should be connected by switch port 7 to 8, 7
•
to 8, 7 to 8... throughout the ring
Define switch port 7 as FRNT port 1 and switch port 8
•
as FRNT port 2 on all switches.
One switch in the ring must be configured as "Focal Point"
•
2. FRNT ring using copper cables
The rules are as follows:
The switches should be connected by switch port 5 to 6, 5
•
to 6, 5 to 6... throughout the ring
Define switch port 5 as FRNT port 1 and switch port 6
•
as FRNT port 2 on all switches.
One switch in the ring must be configured as "Focal Point"
•
3. FRNT ring using fibre and copper cables
The rules are as follows:
The switches should be connected by switch port 7 to port 8 where you are using
•
fibre cable and switch port 5 to 6 where you are using copper cable.
Define switch port 7 as FRNT port 1 and switch port 8 as FRNT port 2 on all
•
switches where you are using fibre cable. Define switch port 5 as FRNT port 1 and
switch port 6 as FRNT port 2 on all switches where you are using copper cable.
One switch in the ring must be configured as "Focal Point"
•