Location of interface ports and led’s, Ethernet connection tx (6 ports), Power connection screw terminal fault contact – Westermo Lynx 100 User Manual
Page 12

12
6640-2205
Location of interface ports and LED’s
Ethernet connection TX (6 ports)
Contact Signale Direction Description
No.1
TD+
In/Out
Transmitted/Received data
No. 2
TD–
In/Out
Transmitted/Received data
No. 3
RD+
In/Out
Transmitted/Received data
No. 4
–
Not Connected
No. 5
–
Not Connected
No. 6
RD–
In/Out
Transmitted/Received data
No. 7
–
Not Connected
No. 8
–
Not Connected
Shield
HF-connected
NOTE! Railway installation close to the rails.
For a cable located inside 3 m boundary and connected to this
port, the use of shielded cable is recommended, this is to mini-
mise the risk of interference. The cable shield should be prop-
erly connected (360°) to an earthing point within 1 m from
this port. This earthing point should have a low impedance con-
nection to the conductive enclosure of the apparatus cabinet,
or similar, where the unit is built-in. This conductive enclosure
should be connected to the earthing system of an installation
and may be directly connected to the protective earth.
LED Indicators (for details see page 13)
Power, screw terminal (for details see below)
FX(Fibre)
(for details see page 11)
Fault contact (for details see below)
4-position
Description
No. 1
+DC1
No. 2
+DC2
No. 3
Common
No. 4
Common
The Lynx series supports redundant
power connection. The positive inputs
are +DC1 and +DC2, the negative input
for both supplies is –COM. Connect
the primary voltage (e.g. +24 VDC) to
the +DC1 pin and ground to one of the
–COM pins on the power input on the
Lynx switch by using the enclosed power.
4-position
Description
No. 1
Alarm relay (status) +
No. 2
Alarm relay (status) –
No. 3
–
No. 4
–
W
estermo
Teleindustri www
.westermo.com
Input voltage: 19-60VDC max 7W Date of mfg (Y/M/D): 2006-10-17
MAC: 00:07:7c:80:24:ae Serial no: lx4232
Lynx 3640-4030
L1407F1- MM-SX-LC550
+DC1
+DC2
-COM
-COM
Power connection
screw terminal
Fault contact
W
estermo
Laser Class 1 Product
Digital in -
Digital in +
Status -
Status +
W
estermo T
eleindustri
AB
SE-640 40 Stora Sundby Sweden
Sweden www
.westermo.com
lx003967
Country of origin: