beautypg.com

Ratings, Safety control drawing – Westermo EDW-100 User Manual

Page 5

background image

5

6616-2203

Ratings

Power

12 – 48 VDC; 250 mA

Ambient temperature

–25ºC ≤ Ta ≤ +70ºC

Ingress protection (IP)

IP21

Maximum surface temperatur 135ºC (temperature class T4)

Safety Control Drawing

Position

Descripton

Input / Output values

1

In/Out / TD+

U = ± 1 V (4μV/s)
I = ± 20 mA
Data rate:
10/100 Mbit/s

2

In/Out / TD–

3

In/Out / RD+

4

Not connected

5

Not connected

6

In/Out / RD–

7

Not connected

8

Not connected

Galvanically isolated via signal transformer and capacitively

isolated to signal ground through a 3 kV 470 pF capacitor.

See user manual for proven transient protection.

Position

Descripton

Input values

1

In / Common

U

min/max

= 10 – 60 VDC

I

max

= 300 mA

P

max

= 3 W

2

In / +Voltage A

3

In / +Voltage B

4

In / Common

See section Type tests and environmental conditions in this user

manual for proven transient protection.

1234

1234

Degree of protection

IP 21

Ambient temperature

–25°C to +70°C

Installation spacing

Minimum 25 mm above / below
Minimum 10 mm left / right

Position Descripton

Input /Output values

1

Not connected (DCD)

U

max

= ± 12 Vpk

I

max

= ± 60 mA

Data rate:
0.3 – 115.2 kbit/s

2

In / Received Data (RD)

3

Out / Transmitted Data (TD)

4

Out / Data Terminal Ready (DTR)

5

– / Signal Ground (SG)

6

In / Data Set Ready (DSR)

7

Out / Request To Send (RTS)

8

In / Clear To Send (CTS)

9

Not connected

Position Descripton

Input / Output values

1

In / R+ line RS-422

U

max

= ± 5 Vpk

I

max

= ± 250 mA

Data rate:
0.3 – 115.2 kbit/s

2

In / R– line RS-422

3

In/out / T+ line RS-422/485

4

In/out / T– line RS-422/485