Led indicators, Ethernet – Westermo EDW-100 User Manual
Page 26
26
6616-2203
LED Indicators
8
7
6
5
4
3
2
1
Ethernet
Ethernet TX connection (RJ-45 connector), automatic MDI/MDI-X crossover*.
CAT 5 cable is
recommended.
Unshielded (UTP)
or shielded (STP)
connector might be
used.
* Depend of settings on S1; 6, 7 and 8.
Contact
Signal Name
Direction Description/Remark
1
TD+
In/Out
Transmitted/Received data
2
TD–
In/Out
Transmitted/Received data
3
RD+
In/Out
Transmitted/Received data
4
NC
5
NC
6
RD–
In/Out
Transmitted/Received data
7
NC
8
NC
Shield
HF-connected
LED
Status Description
PWR
Power
OFF
No internal power
ON
Internal Power OK
TD
Transmit data
OFF
No serial data transmitted from the unit,
(RS-232 or RS-422/485)
ON
Serial data transmitted from the unit, (RS-232 or RS-422/485)
RD
Receive data
OFF
No serial data received to the unit, (RS-232 or RS-422/485)
ON
Serial data received to the unit, (RS-232 or RS-422/485)
RTS
Request to send
OFF
No RTS to the RS-232 interface or RS-422/485 transmitting.
ON
RTS to the RS-232 interface or RS-422/485 receiving.
CTS
Clear to send
OFF
No CTS from the RS-232 interface
ON
CTS from the RS-232 interface
LINK
OFF
No Ethernet link.
Cable not connected.
ON
Good Ethernet link.
Flash
Ethernet data is transmitted or received, traffic indication.
STAT
Status
OFF
Normally Off
ON
Telnet session established to Telnet diagnostics service or
Ongoing configuration by Web tool
RC
Remotely controlled
OFF
DIP switch settings are valid.
ON
One or more DIP switches are overrid by remote configuration
SPD
Speed Integrated in RJ-45
Green
ON
Ethernet 100 Mbit/s
OFF
Ethernet 10 Mbit/s
DPX
Duplex Integrated in RJ-45
Yellow
ON
Full duplex
OFF
Half duplex