Type tests and environmental conditions – Westermo EDW-120 User Manual
Page 9
9
6616-2211
Type tests and environmental conditions
Electromagnetic Compatibility
Phenomena
Test
Description
Test levels
ESD
EN 61000-4-2
Enclosure contact
± 6 kV
Enclosure air
± 8 kV
RF field AM
modulated
IEC 61000-4-3
Enclosure
20V/m 80% AM (1 kHz), 80 – 2 000 MHz
12V/m 80% AM (1 kHz), 2 000 – 2 700 MHz
RF field 900 MHz
ENV 50204
Enclosure
20 V/m pulse modulated 200 Hz, 900 ± 5 MHz
Fast transient
EN 61000-4-4
Signal ports
± 2 kV
Power ports
± 2 kV
Surge
EN 61000-4-5
Signal ports
unbalanced
± 2 kV line to earth, ± 2 kV line to line
Signal ports balanced
± 2 kV line to earth, ± 1 kV line to line
Power ports
± 2 kV line to earth, ± 2 kV line to line
RF conducted
EN 61000-4-6
Signal ports
10 V 80% AM (1 kHz), 0.15 – 80 MHz
Power ports
10 V 80% AM (1 kHz), 0.15 – 80 MHz
Pulse magnetic field
EN 61000-4-9
Enclosure
1000 A/m, 6.4 / 16 μs pulse
Voltage dips
and interruption
EN 61000-4-29 DC power ports
10 & 100 ms, interruption
10 ms, 30% reduction
10 ms, 60% reduction
+20% above & –20% below rated voltage
Radiated emission
EN 55022
Enclosure
Class A
FCC part 15
Class A
Conducted emission
EN 55022
DC power ports
Class B
Dielectric strength
EN 60950
Signal port to other
isolated ports
1.5 kVrms 50 Hz 1 min
Power port to other
isolated ports
2 kVrms 50 Hz 1 min
Environmental
Temperature
Operating
–25 to +70ºC
Storage & Transport
–40 to +70ºC
Maximum surface
temperature
135ºC (temperature class T4)
Humidity
Operating
5 to 95% relative humidity
Storage & Transport
5 to 95% relative humidity
Altitude
Operating
2 000 m / 70 kPa
Service life
Operating
10 year
Vibration
IEC 60068-2-6
Operating
7.5 mm, 5 – 8 Hz
2 g, 8 – 500 Hz
Shock
IEC 60068-2-27 Operating
15 g, 11 ms
Packaging
Enclosure
EDW-120
UL 94
PC / ABS
Flammability class V-1
EDW-120 Ex
–
Cabelec CA6141
–
Dimension
W x H x D
35 x 121 x 121 mm
Weight
0.2 kg
Degree of protection
IEC 529
Enclosure
IP 21
Cooling
Convection
Mounting
Horizontal on 35 mm DIN-rail