Westermo EDW-120 User Manual
Page 23
23
6616-2211
* To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m
boundary to the rails and connected to this port.
The cable shield should be properly connected (360°) to an earthing point within 1 m from this port. This earthing
point should have a low impedance connection to the conductive enclosure of the apparatus cabinet, or similar,
where the unit is built-in. This conductive enclosure should be connected to the earthing system of an installation
and may be directly connected to the protective earth.
Ethernet 1
Electrical specification
IEEE std 802.3. 2000 Edition
Data rate
10 Mbit/s or 100 Mbit/s, auto-negotiated or manually
set by DIP-switches
Protocol
UDP, TCP, ICMP, HTTP and ARP
Duplex
Full- or half duplex, auto-negotiated or manually set by DIP-switches
Circuit type
TNV-1
Transmission range
100 m
Isolation to
Power 2 kV
rms
RS-232 1.5 kV
rms
RS-422/485 1.5 kV
rms
Connection
RJ-45 shielded, auto MDI/MDI-X
Shielded cable
Not required, except when installed in Railway applications as
signalling and telecommunications apparatus and located close
to rails*
Conductive housing
Isolated to all other circuits