Type tests and environmental conditions – Westermo AD-01 User Manual
Page 6

6
6612-2202
Type tests and environmental conditions
Electromagnetic Compatibility
Phenomena
Test
Description
Level
EsD
EN 61000-4-2
Enclosure contact
± 4 kV
Enclosure air
± 8 kV
RF field AM modulated
IEC 61000-4-3
Enclosure
10 V/m 80% AM (1 kHz), 80 - 2700 MHz
Fast transient
EN 61000-4-4
signal ports
± 1 kV
Power ports
± 2 kV
surge
EN 61000-4-5
signal ports unbalanced
± 1 kV line to earth, ± 1 kV line to line
signal ports balanced
± 1 kV line to earth, ± 1 kV line to line
Power ports
± 2 kV line to earth, ± 2 kV line to line
RF conducted
EN 61000-4-6
signal ports
10 V 80% AM (1 kHz), 0.15 – 80 MHz
Power ports
10 V 80% AM (1 kHz), 0.15 – 80 MHz
Voltage dips and
interruption
EN 61000-4-11
AC power ports
10, 20 & 5000 ms, interruption
200 ms, 60% reduction
500 ms, 30% reduction
Radiated emission
EN 55022
Enclosure
Class B
Conducted emission
EN 55022
AC power ports
Class B
Dielectric strength
EN 60950
signal port to all other
isolated ports
2 kVrms 50 Hz 1min
Power port to other
isolated ports
3 kVrms 50 Hz 1min
2 kVrms 50 Hz 1min (@ rated power < 60V)
Environmental
Temperature
Operating
–0 to +50°C
storage & Transport
-25 to +70°C
Humidity
Operating
5 to 95% relative humidity
storage & Transport
5 to 95% relative humidity
Altitude
Operating
2 000 m / 70 kPa
service life
Operating
10 years
Vibration
IEC 60068-2-6
Operating
7.5 mm, 5 – 8 Hz
2 g, 8 – 500 Hz
shock
IEC 60068-2-27
Operating
15 g, 11 ms
Packaging
Enclosure
uL 94
PC / ABs
Flammability class V-1
Dimension W x H x D
55 x 100 x 128 mm
Weight
0.9 kg
Degree of protection
IEC 529
Enclosure
IP 20
Cooling
Convection
Mounting
Horizontal on 35 mm DIN-rail