beautypg.com

Safety control drawing, Dc power supply ac power supply – Westermo RFIR-xxx User Manual

Page 6

background image

6

6641-22810

Safety control drawing

Position Direction/

description

Input/Output values

DO+

IO / Status +

U

in

= 60 VDC max

DO-

IO / Status –

I

in

= 80 mA max

DI+

IO / Digital in +

U

in

= 60 VDC max

DI-

IO / Digital in –

I

in

= 2.9 mA max

Position Direction/

description

Output values

1

In / VBUS

U = 5 VDC max
I = 100 mA max

2

In/out / D–

3

In/out / D+

4

Not connected

5

Functional earth

Degree of protection:

IP 40

Ambient temperature:

–40 °C to +70 °C (DC), –40 °C to +55 °C (AC)

Position Direction/

description

Input/output values

1

In/out / BI_DA+

Per port:

U = ± 1 V (4V/us)

I = ± 20 mA
Data rate:

10/100/1000 Mbit/s

2

In/out / BI_DA–

3

In/out / BI_DB+

4

In/out / BI_DC+

5

In/out / BI_DC–

6

In/out / BI_DB–

7

In/out / BI_DD+

8

In/out / BI_DD–

Shield

Functional earth

Galvanically isolated via signal transformers and

capacitively isolated to GND/Functional earth

through a 2kV 1000pF capacitor.

See user manual for proven transient protection.

Position Direction/

description

Output values

1

Out / VBUS

U

out

= 5 VDC max

I

out

= 500 mA max

2

In/out / D–

3

In/out / D+

4

GND

Shield

Functional earth

Direction/

description Input values
In / +DC1

U

in

= (16 – 60) VDC

I

in

= 2.0 A@16 VDC*

P

In

= 32 W@16 VDC*

In / +DC2
In / COM
In / COM

DC Power supply

AC Power supply

Direction/

description Input values
In / P

U

in

= (100–240) VAC,

50–60 Hz
I

in

= 360 mA@100 VAC**

In / N
In / NC
In /

+DC1

+DC2

COM

COM

DC

* RFIR-227-T7G-F4G-DC
** RFIR-227-T7G-F4G-AC