Westermo RFIR-xxx User Manual

Page 16

background image

16

6641-22810

Ethernet TX
Electrical specification

IEEE std 802.3. 2005 Edition

Data rate

10 Mbit/s, 100 Mbit/s, 1000 Mbit/s, manual or auto

Duplex

Full or half, manual or auto

Circuit type

TNV-1

Transmission range

Up to 150 m with CAT5e cable or better

Isolation to

All other

Connection

RJ-45 auto MDI/MDI-X

Shielded cable

Not required, except when installed in Railway applications as
signalling and telecommunications apparatus and located close
to rails*

Conductive housing

Yes

* NOTE! Railway installation close to the rails.
To minimise the risk of interference, a shielded cable is recommended when the cable is located
inside 3 m boundary to the rails and connected to this port.
The cable shield should be properly connected (360°) to an earthing point within 1 m from this
port. This earthing point should have a low impedance connection to the conductive enclosure of
the apparatus cabinet, or similar, where the unit is built-in. This conductive enclosure should be
connected to the earthing system of an installation and may be directly connected to the functional
earth. Refer also to "Safety" section.

+DC1

+DC2

COM

COM

RSTP

FRNT

VPN

ON

DC1

DC2

1

2

1

1

10/100/1000

10/100/1000

10/100 Base-TX

POWER

CONSOLE

IO

2

3

4

5

6

7

8

2

3

4

1

5

6

7

8

2

3

4

Position

Direction*

Description

1

In/Out

BI_DA+

2

In/Out

BI_DA–

3

In/Out

BI_DB+

4

In/Out

BI_DC+

5

In/Out

BI_DC-

6

In/Out

BI_DB-

7

In/Out

BI_DD+

8

In/Out

BI_DD-

Shield

In/Out

Connected to

Functional earth

* Direction relative this unit.

10/100/1000 Mbit/s, TX ports