beautypg.com

Westermo RFIR-xxx User Manual

Page 13

background image

13

6641-22810

Power
Rated voltage

AC models

100 to 240 VAC, 50-60 Hz

DC models

20 to 48 VDC

Operating voltage

AC models

90 to 264 VAC, 47-63 Hz

DC models

16 to 60 VDC

Maximum nominal current

consumption

RFIR-219-F4G-T7G-DC

1120 mA @ 24 VDC
450 mA @ 48 VDC

RFIR-227-F4G-T7G-DC

1250 mA @ 24 VDC
550 mA @ 48 VDC

RFIR-219-F4G-T7G-AC

360 mA @ 100 VAC 60 Hz
200 mA @ 240 VAC 50 Hz

RFIR-227-F4G-T7G-AC

350 mA @ 110 VAC 60Hz
210 mA @ 230 VAC 50Hz

Fuse rating

All models

4A(T)**

Inrush current

DC models

25 mA2 @ 24 VDC
165 mA2 @ 48 VDC

AC models

75 mA2 @ 110 VAC
340 mA2 @ 230 VAC

Startup current*

All models

2x nominal current

Rated frequency

AC models

50/60 Hz

DC models

DC

Polarity

AC models

Not applicable

DC models

Reverse polarity protected

Redundant power input

AC models

No

DC models

Yes

Isolation to

All other

Connection

Detachable screw terminal

Connector size

All models

0.2 – 2.5 mm2
(AWG 24 – 12)

Shielded cable

Not required

* External supply current capability for proper start-up
** Denote time-delay fuse