Current consumption calculation, Led indicators f4g-t4g – Westermo RFI-xx User Manual
Page 26
26
6641-22305
Position
Direction*
Description
1
in/Out
Bi_DA+
2
in/Out
Bi_DA–
3
in/Out
Bi_DB+
4
in/Out
Bi_DC+
5
in/Out
Bi_DC–
6
in/Out
Bi_DB–
7
in/Out
Bi_DD+
8
in/Out
Bi_DD–
shield
in/Out
Connected to Pe
+DC1
+DC2
COM
COM
RSTP
FRNT
VPN
ON
DC1
DC2
1
2
1
1
10/100/1000
10/100/1000
10/100 Base-TX
POWER
CONSOLE
IO
2
3
4
5
6
7
8
2
3
4
1
5
6
7
8
2
3
4
Position
Direction*
Description
rx
in
receive port
Tx
Out
Transmit port
LED indicators F4G-T4G
LED
Status
Description
Copper ports 1 – 4
Fibre ports 5 – 8
OFF
No link.
GreeN
Link established.
GreeN FLAsH
Data traffic indication.
YeLLOW
Port alarm and no link. Or if FrNT or rsTP mode,
port is blocked.
* Direction relative this unit.
* Direction relative this unit
Current consumption calculation
Current consumption values described for each interface is the current consumption
for that interface only. To calculate the total current consumption values shall be added
together.
For example a unit with the following configuration will be calculated as follows:
Used modules
Consumption
Power and CPU
410 mA @ 20 VDC
8 copper ports
144 mA @ 20 VDC
F4G
360 mA @ 20 VDC
Adding the values will give a total consumption of 914 mA @ 20 VDC.
external power supply must be rated to meet the calculated current.
Westermo recommends external power supply to be rated for a startup current which
is at least twice the calculated in service consumption. in the example above an external
power supply must be rated for at least 1828 mA for startup current.