Type tests and environmental conditions – Westermo RFI-xx User Manual
Page 12
12
6641-22305
Type tests and environmental conditions
Phenomena
Test
Description
Test levels
esD
eN 61000-4-2
enclosure contact
± 6 kV
enclosure air
± 8 kV
rF field AM modulated ieC 61000-4-3
enclosure
20 V/m 80% AM (1 kHz), 80 – 2700 MHz
Fast transient
eN 61000-4-4
signal ports
± 2 kV
Power ports
± 2 kV
surge
eN 61000-4-5
signal ports unbalanced
± 2 kV line to earth, ± 2 kV line to line
signal ports balanced
± 2 kV line to earth, ± 1 kV line to line
Power ports
± 2 kV line to earth, ± 1 kV line to line
rF conducted
eN 61000-4-6
signal ports
10 V 80% AM (1 kHz), 0.15 – 80 MHz
Power ports
10 V 80% AM (1 kHz), 0.15 – 80 MHz
Power frequency
magnetic field
eN 61000-4-8
enclosure
Not susceptible to magnetic fields
Pulse magnetic field
eN 61000-4-9
enclosure
300 A/m
Voltage dips
and interruption
eN 61000-4-29
DC power ports
10 & 100 ms, interruption
10 ms, 30% reduction
10 ms, 60% reduction
+20% above & –20% below rated voltage
radiated emission
eN 55022
enclosure
Class A
FCC part 15
enclosure
Class A
Conducted emission
eN 55022
DC power ports
Telecommunication
ports Class B
Class B
Dielectric strength
eN 60950
signal port to other
isolated ports
1.5 kVrms 50 Hz 1 min
Power port to other
isolated ports
1.5 kVrms 50 Hz 1 min
Temperature
Operating
–40 to +70ºC (–40 to +158ºF) (all models*)
storage & Transport
–40 to +85ºC (–40 to +185ºF) (all models)
Maximum surface
temperature
135°C (temperature class T4)
Humidity
Operating
5 to 95% relative humidity
storage & Transport
5 to 95% relative humidity
Altitude
Operating
2 000 m / 70 kPa
service life
Operating
10 year
Vibration
ieC 60068-2-6
Operating
7.5 mm, 5 – 8 Hz
2 g, 8 – 500 Hz
(Wall-mounted or DiN-rail mounted using TH
35-15 according to eN 60175)
shock
ieC 60068-2-27
Operating
15 g, 11 ms
(Wall-mounter or DiN-rail mounted using TH
35-15 according to eN 60175)
enclosure
UL 94
Aluminium / Zink
Flammability class V-0 (all models)
* Note: rFi10-F4G-T4G and rFi18-F4G-T4G needs forced airflow to handle operating temperature above +60°C. This
can be acheived using an external fan or similar. Without forced airflow maximum operating temperature is +60°C.
refer also to "safety" section.