Westermo RFI-xx User Manual
Page 17
17
6641-22305
Ethernet TX
electrical specification
ieee std 802.3. 2005 edition
Data rate
10 Mbit/s or 100 Mbit/s, manual or auto
Duplex
Full or half, manual or auto
Circuit type
TNV-1
Transmission range
Up to 150 m (492 ft) with CAT5e cable or better*
isolation to
All other
Connection
rJ-45 auto MDi/MDi-X
shielded cable
Not required, except when installed in railway applications as
signalling and telecommunications apparatus and located close
to rails*
Conductive housing
Yes
Number of ports
2
* NOTE! railway installation close to the rails.
To minimise the risk of interference, a shielded cable is recommended when the cable is located
inside 3 m boundary to the rails and connected to this port.
The cable shield should be properly connected (360°) to an earthing point within 1 m from this
port. This earthing point should have a low impedance connection to the conductive enclosure of
the apparatus cabinet, or similar, where the unit is built-in. This conductive enclosure should be
connected to the earthing system of an installation and may be directly connected to the protective
earth. refer also to "safety" section.
IO / Relay output
Connect resistance
30 W
isolation to
All other
Connection
Detachable screw terminal
Connector size
0.2 – 2.5 mm
2
(AWG 24 – 12)
Maximum voltage/current
60 VDC / 80 mA
IO / Digital input
Voltage levels
Logic one >12V, Logic zero <1V
isolation to
All other
Connection
Detachable screw terminal
Connector size
0.2 – 2.5 mm
2
(AWG 24 – 12)
Maximum voltage
60 VDC
USB
electrical specification
UsB 2.0 host interface
Data rate
Up to 12 Mbit/s (full-speed mode)
Circuit type
seLV
Maximum supply current
500 mA
isolation to
All other except Console
Connection
UsB receptacle connector type A
Conductive housing
Yes