Westermo FDV-206-1D-1S User Manual
Page 9

9
6660-2201
Ethernet TX
Electrical specification
IEEE std 802.3. 2005 Edition
Data rate
10 Mbit/s, 100 Mbit/s, manual or auto
Duplex
Full or half, manual or auto
Transmission range
150 m, according to long cable specification
Isolation to
All other
Connection
RJ-45 auto MDI/MDIX
Shielded cable
Not required, except when installed in Railway applications as
signalling and telecommunications apparatus and located close
to rails.*
Conductive housing
Yes
Number of ports
4
* To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m
boundary to the rails and connected to this port.
The cable shield should be properly connected (360º) to an earthing point within 1 m from this port.
This earthing point should have a low impedance connection to the conductive enclosure of the apparatus
cabinet, or similar, where the unit is built-in. This conductive enclosure should be connected to the earthing
system of an installation and may be directly connected to the protective earth.
Console
Electrical specification
TTL-level
Data rate
115.2 kbit/s
Data format
8 data bits, none parity, 1 stop bit, no flow control
Circuit type
SELV
Transmission range
15 m
Isolation to
Power, DSL, Ethernet
Galvanic connection to
Serial, USB
Connection
2.5 mm jack, use Westermo cable 1211-2027