beautypg.com

Westermo FDV-206-1D-1S User Manual

Page 9

background image

9

6660-2201

Ethernet TX

Electrical specification

IEEE std 802.3. 2005 Edition

Data rate

10 Mbit/s, 100 Mbit/s, manual or auto

Duplex

Full or half, manual or auto

Transmission range

150 m, according to long cable specification

Isolation to

All other

Connection

RJ-45 auto MDI/MDIX

Shielded cable

Not required, except when installed in Railway applications as
signalling and telecommunications apparatus and located close
to rails.*

Conductive housing

Yes

Number of ports

4

* To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m
boundary to the rails and connected to this port.
The cable shield should be properly connected (360º) to an earthing point within 1 m from this port.
This earthing point should have a low impedance connection to the conductive enclosure of the apparatus
cabinet, or similar, where the unit is built-in. This conductive enclosure should be connected to the earthing
system of an installation and may be directly connected to the protective earth.

Console
Electrical specification

TTL-level

Data rate

115.2 kbit/s

Data format

8 data bits, none parity, 1 stop bit, no flow control

Circuit type

SELV

Transmission range

15 m

Isolation to

Power, DSL, Ethernet

Galvanic connection to

Serial, USB

Connection

2.5 mm jack, use Westermo cable 1211-2027